Must be placed on all service wires, either overhead or underground, as near as possible to the point where they enter the building and inside the walls, and arranged to cut off the entire current from the building. Science and Industry - Էջ 2581902Ամբողջությամբ դիտվող - Այս գրքի մասին
| American Institute of Electrical Engineers - 1897 - 710 էջ
...construction, Nos. 44. and 43.) a. Must be placed on all service wires, either overhead or underground, as near as possible to the point where they enter the building...arranged to cut off the entire current from the building. Where the switch required by Rule No. 22 is inside the building, the cut-out required by this section... | |
| American Society of Mechanical Engineers - 1898 - 1122 էջ
...No». 44 and 45.) a. Must be placed on all service wires, either overhead or under" ground, as near as possible to the point where they enter the building and inside the walls, and be arranged to cut off the entire current from the building. Where the switch required by Rule No.... | |
| Horatio Alvah Foster - 1901 - 1018 էջ
...construction Nos. 52 and 53.) a. Must be placed on all service wires, either overhead or underground, as near as possible to the point where they enter the building and inside the walls, and arranged to cut oil the entire current from the building. "Where the switch required by rule No. 22 is inside the building,... | |
| Francis Bacon Crocker - 1901 - 528 էջ
...each of all service wires as near as possible to the point where they enter the building, on inside of the walls, and arranged to cut off the entire current from the building. The wires then run to the service switch, which should be capable of opening the circuit when carrying... | |
| 1902 - 738 էջ
...and Circuit-Breakers) a. Must be placed on all service wires, either overhead or underground, as near as possible to the point where they enter the building...arranged to cut off the entire current from the building. Where the required switch is inside the building, the cutout required by this section must be placed... | |
| George Velten Steeb - 1902 - 230 էջ
...cut-outs, fuses, or circuit-breakers on all service wires, either overhead or underground, as near as possible to the point where they enter the building...arranged to cut off the entire current from the building, must be placed at every point where a change is made in the size of the wire, unless the cut-out in... | |
| Harry Cooke Cushing - 1902 - 204 էջ
...all service wires as near as possible to the point where they enter the building, on the inside of the walls, and arranged to cut off the entire current from the building. The cut-out or circuit breaker should always be the first thing that the service wires are connected... | |
| American School (Lansing, Ill.) - 1903 - 320 էջ
...all service wires as near as possible to the point where they enter the building, on the inside of the walls, and arranged to cut off the entire current from the building. The cut-out or circuit breaker should always be the first thing that the service wires are connected... | |
| 1905 - 484 էջ
...all service wires as near as possible to the point where they enter the building, on the inside of the walls, and arranged to cut off the entire current from the building. The cut-out or circuit breaker should always be the first thing that the service wires are connected... | |
| 1906 - 544 էջ
...are also provided. a. Must be placed on all service wires, either overhead or underground, as near as possible to the point where they enter the building...arranged to cut off the entire current from the building. Where the required switch is inside the building, the cutout required by this section must be placed... | |
| |