" In all wiring special attention must be paid to the mechanical execution of the work. Careful and neat running, connecting, soldering, taping of conductors and securing and attaching of fittings, are specially conducive to security and efficiency, and... "
Science and Industry - Էջ 258
1902
Ամբողջությամբ դիտվող - Այս գրքի մասին

Electric Wiring Specifications for Incandescent Lighting

George H. Kimber - 1896 - 80 էջ
...SUGGESTIONS. In all electric work, conductors, however well insulated, should always be treated as hare, to the end that under no conditions, existing or likely...security and efficiency, and will be strongly insisted on. In laying out an installation the work should, if possible, be started from a center of distribution,...
Ամբողջությամբ դիտվող - Այս գրքի մասին

The National Electrical Code: An Analysis and Explanation of the ...

Richard Henry Pierce - 1896 - 234 էջ
...workmanship: GENERAL SUGGESTIONS: — In all electric work conductors, however well insulated, should always be treated as bare, to the end that under no conditions,...work. Careful and neat running, connecting, soldering, tapping of conductors and securing and attaching of fittings, are especially conducive to security...
Ամբողջությամբ դիտվող - Այս գրքի մասին

Transactions of the American Institute of Electrical Engineers

American Institute of Electrical Engineers - 1897 - 710 էջ
...to 71. GENERAL SUGGESTIONS. In all electric work conductors, however well insulated, should always be treated as bare, to the end that under no conditions,...work. Careful and neat running, connecting, soldering, tapping of conductors and securing and attaching of fittings, are specially conducive to security and...
Ամբողջությամբ դիտվող - Այս գրքի մասին

Transactions of the American Society of Mechanical Engineers, Հատոր 19

American Society of Mechanical Engineers - 1898 - 1122 էջ
...(ex-officio). GENERAL SUGGESTIONS. In all electric work, conductors, however well insulated, should always be treated as bare, to the end that under no conditions,...security and efficiency and will be strongly insisted on. In laying out an installation, except for constant-current systems, the work should, if possible,...
Ամբողջությամբ դիտվող - Այս գրքի մասին

The State Historical Society of Wisconsin: The story of its growth. Opinions ...

Reuben Gold Thwaites - 1898 - 212 էջ
...any conditions. All distributinig or circuit wires shall extend without a joint to the farthest lamp. Special attention must be paid to the mechanical execution...and neat running, connecting, soldering, taping of all wires, and securing and attachment of fittings, will be strongly insisted upon. FEEDERS. From the...
Ամբողջությամբ դիտվող - Այս գրքի մասին

Distributing system and lamps

Francis Bacon Crocker - 1901 - 528 էջ
...minute. GENERAL SUGGESTIONS. In all electric work conductors, however well insulated, should always be treated as bare, to the end that under no conditions,...security and efficiency, and will be strongly insisted on. In laying out an installation, except for constant-current systems, the work should, if possible,...
Ամբողջությամբ դիտվող - Այս գրքի մասին

Distributing system and lamps

Francis Bacon Crocker - 1901 - 514 էջ
...SUGGESTIONS. In all electric work conductors, however well insulated, should always be treated as-bare, to the end that under no conditions, existing or likely...security and efficiency, and will be strongly insisted on. In laying out an installation, except for constant-current systems, the work should, if possible,...
Ամբողջությամբ դիտվող - Այս գրքի մասին

Electrical Engineer's Pocket-book: A Hand-book of Useful Data for ...

Horatio Alvah Foster - 1901 - 1018 էջ
...revolutions per minute. <-I \B It t I In all electric work conductors, however well insulated, should always be treated as bare, to the end that under no conditions,...are specially conducive to security and efficiency, ami will be strongly insisted on. In laying out an installation, except for constant-current systems,...
Ամբողջությամբ դիտվող - Այս գրքի մասին

Agents' and Inspectators Pocket-book of Fire Protection

George Velten Steeb - 1902 - 230 էջ
...treated as bare, to the end that under no conditions, existing or likely to exist, can a grounding cr short circuit occur, and so that all leakage from...security and efficiency, and will be strongly insisted on. In laying out an installation, except for constant-current systems, the work should, if possible,...
Ամբողջությամբ դիտվող - Այս գրքի մասին

Handbook for Architects and Builders, Հատոր 11

1908 - 358 էջ
...connections. GENERAL SUGGESTIONS. In all electric work conductors, however well insulated, should always be treated as bare, to the end that under no conditions,...conductors and securing and attaching of fittings, are especially conducive to security and efficiency, and will be strongly insisted on. In laying out an...