Provisions must be made to allow rapid and complete drainage of the cowling in normal ground and flight attitudes. Drains must not discharge In locations constituting a fire hazard. Basic Glider Criteria Handbook - Էջ 135United States. Flight Standards Service - 1962 - 139 էջԱմբողջությամբ դիտվող - Այս գրքի մասին
| Philippines - 2001 - 678 էջ
...normally subjected. (b) Provisions must be made to allow rapid and complete drainage of the cowling in normal ground and flight attitudes. Drains must not...discharge in locations constituting a fire hazard. Parts of the cowling that are subjected to high temperatures because they are near exhaust system parts... | |
| United States. Bureau of Air Commerce - 1963 - 168 էջ
...resisting all vibration, inertia, and air loads to which it may normally be subjected. Provision shall be made to permit rapid and complete drainage of all...portions of the cowling in all normal ground- and flight altitudes. Drains shall not discharge in locations constituting a fire hazard. Cowling, unless otherwise... | |
| 1997 - 836 էջ
...normally subjected. (b) Provisions must be made to allow rapid and complete drainage of the cowling in normal ground and flight attitudes. Drains must not...discharge in locations constituting a fire hazard. Parts of the cowling that are subjected to high temperatures because they are near exhaust system parts... | |
| 1983 - 684 էջ
...normally subjected. (b) Provisions must be made to allow rapid and complete drainage of the cowling in normal ground and flight attitudes. Drains must not...discharge in locations constituting a fire hazard. Parts of the cowling that are subjected to high temperatures because they are near exhaust system parts... | |
| 1991 - 760 էջ
...normally subjected. (b) Provisions must be made to allot rapid and complete drainage of the cowling in normal ground and flight attitudes. Drains must not...discharge in locations constituting a fire hazard. Parts of the cowling that are subjected to high temperatures because they are near exhaust system parts... | |
| 1963 - 1044 էջ
...vibration, inertia, and air loads to which it would be subjected in operation. (b) Provision shall be made to permit rapid and complete drainage of all portions of the cowling or engine compartment in all normal ground and flight attitudes. Drains shall not discharge in locations... | |
| 1964 - 918 էջ
...vibration, Inertia, and air loads to which it would be subjected in operation. (b) Provision shall be made to permit rapid and complete drainage of all portions of the cowling or engine compartment in all normal ground and flight attitudes. Drains shall not discharge in locations... | |
| 1967 - 676 էջ
...normally subjected. (b) Provisions must be made to allow rapid and complete drainage of the cowling in normal ground and flight attitudes. Drains must not discharge in locations constituting a flre hazard. Parts of the cowling that are subjected to high temperatures because they are near exhaust... | |
| 1964 - 672 էջ
...resisting all vibration, inertia, and air loads to which it may normally be subjected. Provision shall be made to permit rapid and complete drainage of all...portions of the cowling in all normal ground and flight altitudes. Drains shall not discharge in locations constituting a fire hazard. Cowling, unless otherwise... | |
| 1964 - 1688 էջ
...resisting all vibration, inertia, and air loads to which it may normally be subjected. Provision shall be made to permit rapid and complete drainage of all portions of the cowling in all normal ground and Sight attitudes. Drains shall not discharge hi locations constituting a fire hazard. Cowling, unless... | |
| |