| Philippines - 2001 - 678 էջ
...engine debris, or other likely debris. (b) All covers must be fire resistant and have the capacity to perform the intended functions under the heat and other conditions likely to occur when there is a fire. § 121.317 Passenger information. (a) No person may operate an aircraft unless... | |
| United States. Bureau of Air Commerce - 1963 - 168 էջ
...fluidcarrying lines, this term refers to a line and fitting assembly which will perform its intended protective functions under the heat and other conditions likely to occur at the particular location. Flame-resistant. Flame-resistant material means a material which will not support combustion to the... | |
| 1939 - 1520 էջ
...fluid-carrying lines, this term refers to a line and fitting assembly which will perform its intended protective functions under the heat and other conditions likely to occur at the particular location. (c) Flame-resistant. "Flame-resistant" material means material which will not support combustion to... | |
| 1963 - 1044 էջ
...second) , and B= rotor radius (ft.). (1) Fire protection — (1) Fireproof. Fireproof material means a material which will withstand heat at least as well...to the point of propagating, beyond safe limits, a fiame after the removal of the ignition source. (4) Flash-resistant. Flash-resistant material means... | |
| 1965 - 480 էջ
...flammable fluid system parts, wiring, air ducts, fittings, and powerplant controls, means the capacity to perform the intended functions under the heat and other conditions likely to occur at the place concerned. "Flame resistant" means not susceptible to combustion to the point of propagating... | |
| 1965 - 1938 էջ
...flammable fluid system parts, wiring, air ducts, fittings, and powerplant controls, means the capacity to perform the intended functions under the heat and other conditions likely to occur at the place concerned. "Flame resistant" means not susceptible to combustion to the point of propagating... | |
| 2001 - 1142 էջ
...lines, fluid system parts, wiring, air ducts, fittings, and powerplant controls, means the capacity to perform the intended functions under the heat and other conditions likely to occur when there is a fire at the place concerned. Flame resistant means not susceptible to combustion to... | |
| 1957 - 1118 էջ
...fluid-carrying lines, this term refers to a line and fitting assembly which will perform its intended protective functions under the heat and other conditions likely to occur at the particular location. Flame-resistant. Flame-resistant material means a material which will not support combustion to the... | |
| 1964 - 1108 էջ
...dimensions appropriate for the purpose for which it is to be used. When applied to fluid -carrying lines, other flammable fluid system components, wiring,...likely to occur at the particular location. • 3) Flame -resistant. Plame-resistant material means material which will not support combustion to the... | |
| 1964 - 672 էջ
...fluidcarrying lines, this term refers to a line and fitting assembly which will perform its intended protective functions under the heat and other conditions likely to occur at the particular location. Flame-resistant. Flame-resistant material means a material which will not support combustion to the... | |
| |