" All members of the structure shall be suitably protected against deterioration or loss of strength in service due to weathering, corrosion, abrasion, or other causes. In seaplanes, special... "
Code of Federal Regulations: Containing a Codification of Documents of ... - Էջ 196
1962
Ամբողջությամբ դիտվող - Այս գրքի մասին

The Code of Federal Regulations of the United States of America

1973 - 720 էջ
...PR 14533, Sept. 27, 1968] § 27.609 Protection of structure. Each part of the structure must — (a) Be suitably protected against deterioration or loss of strength In service due to any cause, including — (1) Weathering; (2) Corrosion; and (3) Abrasion; and (b) Have provisions for...
Ամբողջությամբ դիտվող - Այս գրքի մասին

The Code of Federal Regulations of the United States of America

1968 - 616 էջ
...on bolts that are subject to rotation in service. § 31.39 Protection. Each part of the balloon must be suitably protected against deterioration or loss of strength in service due to weathering, corrosion, or other causes. § 31.41 Inspection provisions. There must be a means to allow...
Ամբողջությամբ դիտվող - Այս գրքի մասին

The Code of Federal Regulations of the United States of America

1970 - 684 էջ
...FR 14533, Sept. 27. 1968] § 27.609 Protection of structure. Each part of the structure must — (a) Be suitably protected against deterioration or loss of strength in service due to any cause, including — (1) Weathering; (2) Corrosion; and (3) Abrasion; and (b) Have provisions for...
Ամբողջությամբ դիտվող - Այս գրքի մասին

The Code of Federal Regulations of the United States of America

1967 - 596 էջ
...to rotation in operation. § 23.609 Protection of structure. Each part of the structure must — (a) Be suitably protected against deterioration or loss of strength in service due to any cause, including — (1) Weathering; (2) Corrosion; and (3) Abrasion; and (b) Have adequate provisions...
Ամբողջությամբ դիտվող - Այս գրքի մասին

The Code of Federal Regulations of the United States of America

1972 - 706 էջ
...35 PB 5674, Apr. 8, 1970] § 25.609 Protection of structure. Each part of the structure must — (a) Be suitably protected against deterioration or loss of strength in service due to any cause, including — (1) Weathering; (2) Corrosion; and (3) Abrasion; and (b) Have provisions for...
Ամբողջությամբ դիտվող - Այս գրքի մասին

The Code of Federal Regulations of the United States of America

1965 - 490 էջ
...to rotation in operation. § 27.609 Protection of structure. Each part of the structure must — (a) Be suitably protected against deterioration or loss of strength in service due to any cause, including — (1) Weathering; (2) Corrosion; and (3) Abrasion; and (b) Have provisions for...
Ամբողջությամբ դիտվող - Այս գրքի մասին

The Code of Federal Regulations of the United States of America

1969 - 636 էջ
...to rotation in operation. § 23.609 Protection of structure. Each part of the structure must — (a) Be suitably protected against deterioration or loss of strength in service due to any cause, including — (1) Weathering; (2) Corrosion; and (3) Abrasion; and (b) Have adequate provisions...
Ամբողջությամբ դիտվող - Այս գրքի մասին

The Code of Federal Regulations of the United States of America

1971 - 702 էջ
...PR 14533, Sept. 27, 1968] § 27.609 Protection of structure. Each part of the structure must — (a) Be suitably protected against deterioration or loss of strength in service due to any cause, including — (1) Weathering; (2) Corrosion; and (3) Abrasion; and (b) Have provisions for...